OVHcloud US Web Run Tests
C3-4 - Mar 21 2026

Go to OVHcloud US



Web Run tests are made of a load test tool and a database intensive Rails web application.

The load test tool sends HTTP requests to the web application at a controlled rate and records HTTP response codes, response latencies and timeouts. The load test tool is multithreaded and runs on the same VPS where the web application runs.

The intent is to measure:

  • the response times (latency) of the web server
  • the amount of CPU used to serve those requests under various load levels
  • what's the maximum load at which 100% requests are served without timing out.

Provider: OVHcloud US
Plan: C3-4
Location: Oregon, USA
Number of CPU cores: 2
CPU type: AMD EPYC-Milan Processor

Web Runs by request rate


Note: the P99 is the 99th percentile. The P99 latency is the latency of the 1% slowest HTTP requests in the web run.


Rate (reqs/s) Average Latency P99 Latency CPU idle CPU steal Successful requests Timed out requests Duration (minutes)
1 39ms 110ms 97% 0.00% 304 0 5
5 32ms 54ms 68% 0.00% 1504 0 5
10 32ms 50ms 82% 0.00% 6004 0 10
15 32ms 54ms 73% 0.01% 4505 0 5
30 32ms 50ms 48% 0.01% 9012 0 5
45 31ms 48ms 24% 0.01% 13518 0 5
50 31ms 48ms 16% 0.02% 15024 0 5
60 32ms 50ms 0% 0.02% 17639 361 5
70 31ms 48ms 0% 0.01% 17925 3075 5

Be the first to learn about new Best VPS rankings. Subscribe to our newsletter.